<modbus enabled="True" host="0.0.0.0" port="502">
|
||
|
<device_info>
|
||
|
<VendorName>Siemens</VendorName>
|
||
|
<ProductCode>SIMATIC</ProductCode>
|
||
|
<MajorMinorRevision>S7-200</MajorMinorRevision>
|
||
|
</device_info>
|
||
|
<mode>serial</mode>
|
||
|
<delay>100</delay>
|
||
|
<slaves>
|
||
|
<slave id="0">
|
||
|
<blocks>
|
||
|
<block name="memoryModbusSlave0BlockA">
|
||
|
<!-- COILS/DISCRETE_OUTPUTS aka. binary output, power on/power off
|
||
|
Here we map modbus addresses 1 to 127 to S7-200 PLC Addresses Q0.0 to Q15.7 -->
|
||
|
<type>COILS</type>
|
||
|
<starting_address>1</starting_address>
|
||
|
<size>128</size>
|
||
|
<content>memoryModbusSlave0BlockA</content>
|
||
|
</block>
|
||
|
<block name="memoryModbusSlave0BlockB">
|
||
|
<!-- CONTACTS/DISCRETE_INPUTS aka. binary input.
|
||
|
Map modbus addresses 10001-10032 to S7-200 PLC inputs starting from I0.0 -->
|
||
|
<type>DISCRETE_INPUTS</type>
|
||
|
<starting_address>10001</starting_address>
|
||
|
<size>32</size>
|
||
|
<content>memoryModbusSlave0BlockB</content>
|
||
|
</block>
|
||
|
</blocks>
|
||
|
</slave>
|
||
|
<slave id="255">
|
||
|
<blocks>
|
||
|
<block name="memoryModbusSlave255BlockA">
|
||
|
<!-- COILS/DISCRETE_OUTPUTS aka. binary output, power on/power off
|
||
|
Here we map modbus addresses 1 to 127 to S7-200 PLC Addresses Q0.0 to Q15.7 -->
|
||
|
<type>COILS</type>
|
||
|
<starting_address>1</starting_address>
|
||
|
<size>128</size>
|
||
|
<content>memoryModbusSlave255BlockA</content>
|
||
|
</block>
|
||
|
<block name="memoryModbusSlave255BlockB">
|
||
|
<!-- CONTACTS/DISCRETE_INPUTS aka. binary input.
|
||
|
Map modbus addresses 10001-10032 to S7-200 PLC inputs starting from I0.0 -->
|
||
|
<type>DISCRETE_INPUTS</type>
|
||
|
<starting_address>10001</starting_address>
|
||
|
<size>32</size>
|
||
|
<content>memoryModbusSlave255BlockB</content>
|
||
|
</block>
|
||
|
</blocks>
|
||
|
</slave>
|
||
|
<slave id="1">
|
||
|
<blocks>
|
||
|
<block name="memoryModbusSlave1BlockA">
|
||
|
<!-- COILS/DISCRETE_OUTPUTS aka. binary output, power on/power off
|
||
|
Here we map modbus addresses 1 to 127 to S7-200 PLC Addresses Q0.0 to Q15.7 -->
|
||
|
<type>COILS</type>
|
||
|
<starting_address>1</starting_address>
|
||
|
<size>128</size>
|
||
|
<content>memoryModbusSlave1BlockA</content>
|
||
|
</block>
|
||
|
<block name="memoryModbusSlave1BlockB">
|
||
|
<!-- CONTACTS/DISCRETE_INPUTS aka. binary input.
|
||
|
Map modbus addresses 10001-10032 to S7-200 PLC inputs starting from I0.0 -->
|
||
|
<type>DISCRETE_INPUTS</type>
|
||
|
<starting_address>10001</starting_address>
|
||
|
<size>32</size>
|
||
|
<content>memoryModbusSlave1BlockB</content>
|
||
|
</block>
|
||
|
</blocks>
|
||
|
</slave>
|
||
|
<slave id="2">
|
||
|
<!-- This slave does some measuring. (analog inputs).
|
||
|
Map modbus addresses 30001-30009 to S7 PLC analog input bits AIW0-AIW8 -->
|
||
|
<blocks>
|
||
|
<block name="memoryModbusSlave2BlockC">
|
||
|
<!-- Will be parsed with eval() -->
|
||
|
<type>ANALOG_INPUTS</type>
|
||
|
<starting_address>30001</starting_address>
|
||
|
<size>8</size>
|
||
|
<content>memoryModbusSlave2BlockC</content>
|
||
|
</block>
|
||
|
<block name="memoryModbusSlave2BlockD">
|
||
|
<!-- Maps to S7-200 PLC addresses HoldStart+8 -->
|
||
|
<type>HOLDING_REGISTERS</type>
|
||
|
<starting_address>40001</starting_address>
|
||
|
<size>8</size>
|
||
|
<content>memoryModbusSlave2BlockD</content>
|
||
|
</block>
|
||
|
</blocks>
|
||
|
</slave>
|
||
|
</slaves>
|
||
|
</modbus>
|